Ningún producto
Estos precios se entienden IVA incluído
VCR-50844-CD0116-160400011
Nuevo
CONDENSADOR VCR 3,1 kVAr 440V (50,8mf)
Fabricante ITALFARAD |
Advertencia: ¡Últimas unidades en stock!
Fecha de disponibilidad:
CONDENSADOR VCR 3,1 kVAr 440V (50,8mf)
LOW VOLTAGE POWER FACTOR CORRECTION SINGLE PHASE CAPACITORS
|
||||||||
Self-healing metallized polypropylene single-phase capacitors, equipped with overpressure safety device. Biodegradable non toxic filling, PCB free. Manufactured using new technologies of metallization. |
||||||||
Technical Data |
||||||||
Capacitance tolerance | -5% +10% | |||||||
Rated frequency | 50 Hz (60 Hz on request) | |||||||
Max working voltage | 1,1 Vn | |||||||
Max overcurrent | 1,3 In | |||||||
Max allowed switch-on current | 100 In | |||||||
Working ambient temperature | -25/D (Max 55°C) | |||||||
Dielectric losses | <0,3 W/kVar | |||||||
Test voltage between terminals | 2,15 Vn 50 Hz x 10 sec. | |||||||
Test voltage between terminals and case | 3 kV x 10 sec.100 In | |||||||
Impulse voltage test | 15 kV (1,2/50 mS) | |||||||
Expected life | 100.000 ore | |||||||
Safety overpressure disconnector | Interno | |||||||
Reference standards | EN 60831-1/2, IEC 831-1/2 | |||||||
It is necessary to allow at least 8 mm for the case expansion. Do not use rigid connections. | ||||||||
CONDENSADOR VCR 3,1 kVAr 440V (50,8mf)
LOW VOLTAGE POWER FACTOR CORRECTION SINGLE PHASE CAPACITORS
|
||||||||
Self-healing metallized polypropylene single-phase capacitors, equipped with overpressure safety device. Biodegradable non toxic filling, PCB free. Manufactured using new technologies of metallization. |
||||||||
Technical Data |
||||||||
Capacitance tolerance | -5% +10% | |||||||
Rated frequency | 50 Hz (60 Hz on request) | |||||||
Max working voltage | 1,1 Vn | |||||||
Max overcurrent | 1,3 In | |||||||
Max allowed switch-on current | 100 In | |||||||
Working ambient temperature | -25/D (Max 55°C) | |||||||
Dielectric losses | <0,3 W/kVar | |||||||
Test voltage between terminals | 2,15 Vn 50 Hz x 10 sec. | |||||||
Test voltage between terminals and case | 3 kV x 10 sec.100 In | |||||||
Impulse voltage test | 15 kV (1,2/50 mS) | |||||||
Expected life | 100.000 ore | |||||||
Safety overpressure disconnector | Interno | |||||||
Reference standards | EN 60831-1/2, IEC 831-1/2 | |||||||
It is necessary to allow at least 8 mm for the case expansion. Do not use rigid connections. | ||||||||